WP-Dynamic Turbine Water Meter for cold water up to 50 º C / PN 16 DN 300
Special Features Hermetically sealed register ( IP 68) Patented hydrodynamically balanced rotor ( dDN 300) .
Patented symmetrical calibration adjustment ( dDN 300) Register may be rotated through 360° .
High overload capability Pattern approved removable measuring element Powder coating affords max.
corrosion protection Not affected by external magnetic fields .
Performance Table Performance data WP-Dynamic 50 º C
Nominal Diameter : DN 300 Size of meter ( acc. to EEC)
Qn 600 Qmax ( ± 2% ) : 2000 m3/ h
maximum peak flow once in life time 24 h
Qmax or 5 min. 1, 2 x Qmax
Qn continuous flow ( ± 2% ) : 1400 m3/ h
Qt transitional flow ( ± 2% ) : 15.0 m3/ h
Qmin minimum flow ( ± 5% ) : 12.0 m3/ h
starting flow m3/ h : 8.0 m3/ h
Performance data according to EEC-specification 30 º C class B
Nominal Diameter DN : 300 Size of meter ( acc. to EEC)
Qn : 600 Qmax maximum peak flow : 1200 m3/ h short time
Qn continuous flow : 600 m3/ h Qt
transitional flow : 120 m3/ h
Qmin minimum flow : 18.0 m3/ h